    Performance:
    URL: Full length of sensor
    Maximum Span: Full length of sensor less Teflon® coating
    Minimum Span: 5.6 inches (70% of probe length)
    Accuracy: ± 1.0% of URL
    Linearity: ± 1.0% of URL
    Repeatability: ± 0.2% of URL
    Resolution/Deadband: 12 bit – 1/4096 of sensor length
    Scan Rate: 10 readings/sec
    Temperature Stability: Unaffected within Process temp range
    Operating / Environmental:
    Range (with 4 – 20 output): 0 to probe length
    Max Turndown (at 20mA): 30% of probe length from top
    Process Temp Limits: 14° to 212° F continuous (-10° to 100°C) Min.
    Media Conductivity: ≥1 Microsiemen SIP
    Temp Limits: 302° F (150° C) for 60 minutes
    Ambient Temp Limits: 32° to 120° F (0° – 50° C)
    Process Pressure Rating: 150 psig (10Bar) max
    Material / Construction
    Housing: 304 Stainless Steel Wetted
    Parts: 316L Stainless Steel – 25 microinch Ra max, PEEK dielectric isolator, Teflon® PFA probe coating
    Process Connections: 1-1/2" – 4" Tri-clamp typical.
    Enclosure Ratings: NEMA 4X, IP-67
    Approvals/Standard: 3-A compliant; Third party verified, CE Compliant
    Power / Signal / Electrical
    Signal
    Output: 4 – 20 mA, Resistance 500 ohms max
    Empty Signal Output: 2.4 mA
    Loop Voltage Required:18 – 36 Vdc
    Power Required: 5.3 Watts max, e.g. 220 mA @ 24Vdc
    Cable: 4 conductor, stranded, 18 – 24 AWG, 0.16 – 0.31 sheath OD for use with field wireable connector Receptacle: M12 5pin single key